Factory supplied easy-to-operate thermostat STC-8080H

Short Description:

This product is a universal single sensor temperature controller;

Refrigeration, frost, transfinite alarm temperature, etc;

Compressor protection delay time is adjustable;

Suitable for cold storage, refrigerated truck refrigeration industry, etc.


  • Service offered: Customized LOGO, labeling, customized packaging boxes, customized products, etc. according to customer requirements
  • Shipment: sea, air, express, door to door transportation services.
  • Fast delivery: 7-10 days to stock up. 10-20 days out of stock.
  • MOQ: 100pcs
  • Samples: samples can be provided and sent out in about 7 days.
  • OEM/0DM Services: Accepted
  • Payment terms: 30% deposit, 70% final payment to delivery
  • Payment methods: bank payment, paypal payment, Western Union and other payment methods, you can also pay RMB
  • Product Detail

    Product Tags

    Our company specializes in R&D, production and sales of microcomputer temperature controllers and humidity controllers. The chip used in the temperature controller has stable performance, complete functions, multiple protections, advanced and reasonable structural design and process processing, and the technical level is internationally advanced and domestically leading . This product has a wide range of applications in the field and industry of freezing and refrigeration and refrigeration maintenance. Our company can also design and customize products according to customer requirements.

    Features and functions

    This product is a universal single sensor temperature controller;
    Refrigeration, frost, transfinite alarm temperature, etc;
    Compressor protection delay time is adjustable;
    Suitable for cold storage, refrigerated truck refrigeration industry, etc.

    Specification

    Product size:75*34.5*85mm
    Front panel size:75*34.5mm
    Installation size:71*29mm

    Technical parameters

    Runtime environment temperature: 0℃~60℃
    Relative humidity: no more than 80% (No condensation)
    Power supply:220VAC±10%,50/60Hz
    Power consumption:<3W
    Temperature measuring range: -50℃~99℃
    Resolution: 1℃
    Accuracy:±1℃
    Compressor delay time: 3 minutes

    Compressor

    ☆When the temperature of the sensor is higher than the set temperature limit and compressor delay exceeds set delay time, relay and the compressor work.
    ☆When the temperature of the sensor is below the set temperature limit relay disconnect compressor stop working.
    ☆When there is a sensor failure, in accordance with the compressor to run for 15 minutes, 30 minutes to stop the proportion of the work.
    Defrosting
    ☆Manual frost: hold down the "▼" key more than 3 seconds, the frost, run after the frost time set automatically stop frost, also can hold the "▼" key again more than 3 seconds, frost is stopped manually.
    ☆Automation: when the compressor total run time reaches the frost period set,Start the frost, compressor stop working at this time, when running after the frost time set, automatic stop frost.
    ☆Close the frost: when a frost cycles or frost time when we have a set to "0" is close function of frost, cannot undertake manual or automated cream.
    Alarm
    ☆Overtemperature alarm: when the temperature is higher than the temperature of the upper limit deviation or below + overtemperature alarm set the temperature of the lower limit - overtemperature alarm deviation, and duration of more than set by overtemperature alarm delay time, the digital tube displays temperature will flash and buzzer noise, press any key to eliminate alarm sound, but the digital tube will continue to shine. Overtemperature alarm deviation can be set to "0", cancel the overtemperature alarm function.

    Check before use and installation requirements

    1, the power supply voltage should be consistent with the voltage marked on the machine.
    2, prohibited to use in the environment of the excessive moisture, banned in high temperature, strong electromagnetic interference, strong corrosive environments.Lead
    3, sensor, power cord and output relay lead, should strictly distinguish, not wrong answer; Overload relay.
    4, to avoid the interference of the introduction, recommend sensor lead keep proper distance with the power cord.
    5, sensor installation, should be far away from the vent as far as possible in order to ensure the accuracy of the measured temperature.